Requirements :





Chiller Key Pad Display Fault and needs to be replaced.

A1, A2 & A3 Compressor Mechanical side need overhauling.

A4 Compressor Winding unbalanced and needs to check.

CFM-6 Nos. Winding is defective and needs to be rewinded.

Breaker is missing 1 no. Needs to be repalced.

Circuit Low Gas, gas charging & replacement of filter drier, oil etc

Transducer faulty, need to be replaced - 3 nos.

B1 & B3 Compressor Mechanical side need overhauling

B2 Compressor Winding Unbalanced. Needs to check.

B4 Compressor is defective and needs overhauling.

CFM Not working - 7 Nos. Needs to be rewinded.

CFM Contactor defective 1-No and needs to be replaced.

Breaker missing 2 nos. Needs to be replaced.

Circuit Low Gas, gas charging & replacement of filter drier, oil etc

Transducer faulty, need to be replaced - 3 nos.

-----------------------



Liquid Line Service Valve is Defective and needs to be replaced

A1, A3 & A4 Compressors are Defective and needs overhauling

1-No Contactor is damage and needs to be replaced.

" 1-No Isolator damage (Model No.77A, NZM4-77-800) and needs

to be replaced. "

CFM-2-Nos is defective and needs to be repaired

Expansion Valve is Defective and needs to be replaced.

" Compressor Crank Heater 4-Nos Defective and needs to be

replaced. "

B1 Compressor defective and needs overhauling.

B3 & B4 Compressor Mechanical side need to Overalling

CFM 4-Nos Defective and needs to be repaired.

Compressor 1-No Contactor is missing & needs to be replaced

Compressor Crank Heater Defective and needs to be replaced



We need a quote and start start immediately. the company will provide best quote will do annual yearly contract
Posted on : 2 years ago
Recurring Requirement : Every 255 Days

    Buyer Details - (Be An Elite Member To View Buyer Details)
Company Name : Ara******
Address :   Sharjah
   
LOGIN HERE
Username :
Password :
Remember Me
 
Forgot Password? Click Here
Not a Member Yet? Sign Up
SIO News
Apr 18, 2018
SNC-Lavalin awarded Wasit Gas Plant installation contract by Saudi Aramco
Apr 14, 2018
E-Showroom from SIO365
Apr 12, 2018
How Businesses Are Saving Big With Publish-Ready Content
Apr 04, 2018
The essential March highlights of Gastech Insights
Apr 02, 2018
The Arab Women in Leadership and Business Summit 2018, April 25-26, 2018

Advertise Here